Step | | Procedure & Parts & Tools |
1 |
|
REMOVE THE 6 SCREWS HOLDING THE HANDLE COVER.
Screwdriver-phillips |
|
|
2 |
|
PULL HANDLE COVER FROM MACHINE.
|
3 |
|
PULL THE SOLUTION SWITCH FROM THE SLOT ON THE HANDLE COVER.
|
4 |
|
PLACE ONE LEAD ON THE SOLUTION SWITCH WIRE AND THE OTHER LEAD ON THE OPPOSITE WIRE. SET THE VOLT METER ON CONTINUITY AND IF THE SOLUTION SWITCH IS GOOD, THE VOLT METER WILL BEEP.
Volt meter (True RMS capable) |
|
|